Validation of minimum data set for home care assessment instrument (MDS-HC) for hong kong chinese elders

  • Chi Wai Kwan
  • , Iris Chi
  • , Tai Pong Lam
  • , Kwok Fai Lam
  • , Kee Lee Chou

Research output: Contribution to journalArticlepeer-review

52 Citations (Scopus)

Abstract

The objective of this study was to validate the Chinese version of Minimum Data Set-Home Care (MDS-HC) in Hong Kong Chinese elders. The respondents were 179 people aged 60 years or older who attend an outpatient clinic in Hong Kong. Firstly, inter-rater reliability was examined and we found acceptable inter-rater reliability. Internal consistency was also obtained for all the composite outcome measures in MDS-HC and most of the Cronbach coefficients were in the range from 0.6 to 0.8. Finally, the concurrent validity of the Chinese version of MDS-HC was assessed by comparing the MDS-HC triggered CAPs and a clinician's diagnoses.We found that high consistency between the results from MDS-HC and clinical judgement in 20 out of 30 CAPs.

Original languageEnglish
Pages (from-to)35-48
Number of pages14
JournalClinical Gerontologist
Volume21
Issue number4
DOIs
Publication statusPublished - 20 Oct 2000
Externally publishedYes

Keywords

  • Appraisal
  • Caregiver depression
  • Self-rated health

Fingerprint

Dive into the research topics of 'Validation of minimum data set for home care assessment instrument (MDS-HC) for hong kong chinese elders'. Together they form a unique fingerprint.

Cite this