TY - JOUR
T1 - Highly Sensitive and Ultrastable Skin Sensors for Biopressure and Bioforce Measurements Based on Hierarchical Microstructures
AU - Sun, Qi Jun
AU - Zhuang, Jiaqing
AU - Venkatesh, Shishir
AU - Zhou, Ye
AU - Han, Su Ting
AU - Wu, Wei
AU - Kong, Ka Wai
AU - Li, Wen Jung
AU - Chen, Xianfeng
AU - Li, Robert K.Y.
AU - Roy, Vellaisamy A.L.
N1 - Publisher Copyright:
© 2018 American Chemical Society.
PY - 2018/1/31
Y1 - 2018/1/31
N2 - Piezoresistive microsensors are considered to be essential components of the future wearable electronic devices. However, the expensive cost, complex fabrication technology, poor stability, and low yield have limited their developments for practical applications. Here, we present a cost-effective, relatively simple, and high-yield fabrication approach to construct highly sensitive and ultrastable piezoresistive sensors using a bioinspired hierarchically structured graphite/polydimethylsiloxane composite as the active layer. In this fabrication, a commercially available sandpaper is employed as the mold to develop the hierarchical structure. Our devices exhibit fascinating performance including an ultrahigh sensitivity (64.3 kPa-1), fast response time (<8 ms), low limit of detection of 0.9 Pa, long-term durability (>100 000 cycles), and high ambient stability (>1 year). The applications of these devices in sensing radial artery pulses, acoustic vibrations, and human body motion are demonstrated, exhibiting their enormous potential use in real-time healthcare monitoring and robotic tactile sensing.
AB - Piezoresistive microsensors are considered to be essential components of the future wearable electronic devices. However, the expensive cost, complex fabrication technology, poor stability, and low yield have limited their developments for practical applications. Here, we present a cost-effective, relatively simple, and high-yield fabrication approach to construct highly sensitive and ultrastable piezoresistive sensors using a bioinspired hierarchically structured graphite/polydimethylsiloxane composite as the active layer. In this fabrication, a commercially available sandpaper is employed as the mold to develop the hierarchical structure. Our devices exhibit fascinating performance including an ultrahigh sensitivity (64.3 kPa-1), fast response time (<8 ms), low limit of detection of 0.9 Pa, long-term durability (>100 000 cycles), and high ambient stability (>1 year). The applications of these devices in sensing radial artery pulses, acoustic vibrations, and human body motion are demonstrated, exhibiting their enormous potential use in real-time healthcare monitoring and robotic tactile sensing.
KW - bioinspired
KW - e-skin
KW - healthcare monitoring
KW - highly sensitive
KW - phonation rehabilitation
UR - http://www.scopus.com/inward/record.url?scp=85041362865&partnerID=8YFLogxK
U2 - 10.1021/acsami.7b16611
DO - 10.1021/acsami.7b16611
M3 - Article
C2 - 29345473
AN - SCOPUS:85041362865
SN - 1944-8244
VL - 10
SP - 4086
EP - 4094
JO - ACS Applied Materials and Interfaces
JF - ACS Applied Materials and Interfaces
IS - 4
ER -