Skip to main navigation Skip to search Skip to main content

Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience

  • Peijian Wei
  • , Yihang Li
  • , Liang Xu
  • , Junyi Wan
  • , Fengwen Zhang
  • , Gary Tse
  • , Jeffrey Shi Kai Chan
  • , Shouzheng Wang
  • , Wenbin Ouyang
  • , Gejun Zhang
  • , Fang Fang
  • , Xiangbin Pan

Research output: Contribution to journal › Article › peer-review

3 Citations (Scopus)

Abstract

Background and Objectives: There is no dedicated occlusive device for closing coronary artery fistulas (CAFs), and specific efficacy and safety data of various off-label occlusive devices for CAFs closure are scarce. Methods: Patients undergoing transcatheter closure of CAFs from January 2011 to December 2022 were included in the single-center retrospective study. The study population was divided into 2 groups: coils group (n=35) and patent ductus arteriosus (PDA) occluders group (n=66). Results: No significant intergroup differences were observed in demographic characteristics except age. The presence of multiple CAF origins (54.3% vs. 4.5%, p<0.001) and multiple draining sites (51.4% vs. 3.0%, p<0.001) were more common in the coils group. In contrast, the presence of aneurysm (72.7% vs. 14.3%, p<0.001), and large fistula (75.8% vs. 37.1%, p<0.001) were more prevalent in the PDA occluders group. The acute procedural success rate of the PDA occluders group was higher compared to that of the coils group (87.9% vs. 62.9%, adjusted odds ratio [OR], 7.20; 95% confidence interval, 1.59–32.64; p=0.01). In addition, no significant intergroup differences were noted in both the recanalization rate (7.8% vs. 20%, p=0.107) and the reintervention rate (3.1% vs. 8.6%, p=0.342). Conclusions: Transcatheter closure of CAFs using PDA occluders was associated with significantly higher acute procedural success rates compared to coil embolization with comparable late outcomes.

Original languageEnglish
Pages (from-to)200-212
Number of pages13
JournalKorean Circulation Journal
Volume55
Issue number3
DOIs
Publication statusPublished - Mar 2025

Keywords

  • Arteriovenous fistulas
  • Coronary vessel anomalies
  • Septal occluder device
  • Therapeutic embolization

Fingerprint

Dive into the research topics of 'Comparison of Embolization Coils and Patent Ductus Arteriosus Occluders for Coronary Artery Fistula Transcatheter Closure: A Single Centre Experience'. Together they form a unique fingerprint.

Cite this