TY - JOUR
T1 - 2D-shear wave elastography
T2 - number of acquisitions can be reduced according to clinical setting
AU - Dioguardi Burgio, Marco
AU - Grégory, Jules
AU - Ronot, Maxime
AU - Sartoris, Riccardo
AU - Chatellier, Gilles
AU - Vilgrain, Valérie
AU - Herrmann, Eva
AU - de Lédinghen, Victor
AU - Cassinotto, Christophe
AU - Chu, Winnie C.W.
AU - Leung, Vivian Y.F.
AU - Ferraioli, Giovanna
AU - Filice, Carlo
AU - Castera, Laurent
AU - Dumortier, Jérôme
AU - Guibal, Aymeric
AU - Pol, Stanislas
AU - Trebicka, Jonel
AU - Jansen, Christian
AU - Strassburg, Christian
AU - Zheng, Rongqin
AU - Zheng, Jian
AU - Francque, Sven
AU - Vanwolleghem, Thomas
AU - Vonghia, Luisa
AU - Manesis, Emanuel K.
AU - Zoumpoulis, Pavlos
AU - Sporea, Ioan
AU - Thiele, Maja
AU - Krag, Aleksander
AU - Friedrich-Rust, Mireen
N1 - Publisher Copyright:
© 2021, The Author(s).
PY - 2021/12
Y1 - 2021/12
N2 - Background: The factors affecting intra-operator variability of two-dimensional shear wave elastography (2D-SWE) have not been clearly established. We evaluated 2D-SWE variability according to the number of measurements, clinical and laboratory features, and liver stiffness measurements (LSM). Methods: At least three LSM were performed in 452 patients who underwent LSM by 2D-SWE (supersonic shear imaging) out of an initial database of 1650 patients. The mean value of the three LSM was our best measurement method. Bland–Altman plots were used to evaluate intra-operator variability when considering only one, or the first two measurements. Variability was assessed by taking the absolute value of the difference between the first LSM and the mean of the three LSM. Logistic regression was used to assess the factors associated with the highest tertile of variability. Results: The limit of agreement was narrower with the mean of the first and second measurements than with each measurement taken separately (− 2.83 to 2.99 kPa vs. − 5.86 to 6.21 kPa and − 5.77 to 5.73 kPa for the first and second measurement, respectively). A BMI ≥ 25 kg/m2 and a first LSM by 2D-SWE ≥ 7.1 kPa increased the odds of higher variability by 3.4 and 3.9, respectively. Adding a second LSM didn’t change the variability in patients with BMI < 25 and a first LSM by 2D-SWE < 7.1 kPa. Conclusions: Intra-operator variability of LSM by 2D-SWE increases with both a high BMI and high LSM value. In patients with BMI < 25 kg/m2 and a first LSM < 7.1 kPa we recommend performing only one LSM.
AB - Background: The factors affecting intra-operator variability of two-dimensional shear wave elastography (2D-SWE) have not been clearly established. We evaluated 2D-SWE variability according to the number of measurements, clinical and laboratory features, and liver stiffness measurements (LSM). Methods: At least three LSM were performed in 452 patients who underwent LSM by 2D-SWE (supersonic shear imaging) out of an initial database of 1650 patients. The mean value of the three LSM was our best measurement method. Bland–Altman plots were used to evaluate intra-operator variability when considering only one, or the first two measurements. Variability was assessed by taking the absolute value of the difference between the first LSM and the mean of the three LSM. Logistic regression was used to assess the factors associated with the highest tertile of variability. Results: The limit of agreement was narrower with the mean of the first and second measurements than with each measurement taken separately (− 2.83 to 2.99 kPa vs. − 5.86 to 6.21 kPa and − 5.77 to 5.73 kPa for the first and second measurement, respectively). A BMI ≥ 25 kg/m2 and a first LSM by 2D-SWE ≥ 7.1 kPa increased the odds of higher variability by 3.4 and 3.9, respectively. Adding a second LSM didn’t change the variability in patients with BMI < 25 and a first LSM by 2D-SWE < 7.1 kPa. Conclusions: Intra-operator variability of LSM by 2D-SWE increases with both a high BMI and high LSM value. In patients with BMI < 25 kg/m2 and a first LSM < 7.1 kPa we recommend performing only one LSM.
KW - Elasticity imaging techniques
KW - Observer variation
KW - Ultrasonography
UR - https://www.scopus.com/pages/publications/85118123707
U2 - 10.1186/s13244-021-01090-7
DO - 10.1186/s13244-021-01090-7
M3 - Article
AN - SCOPUS:85118123707
VL - 12
JO - Insights into Imaging
JF - Insights into Imaging
IS - 1
M1 - 145
ER -